30 kV
30 kV ESD simulators fulfill both ISO 10605 and IEC 61000-4-2 testing requirements.
Models:
esd NX30 Series
- Air- and contact-discharge to 30 kV
- Color touch panel control
- Discharges up to 30 Hz
- 80 easy-to-change R/C-networks and tips
- Switchable Bleed-Off function
- Built-in activity log
- Optional battery tested to 30,000 pulses @30 kV
esd NX30 – Generates ESD pulses according to IEC 61000-4-2 and ISO 10605. Electrostatic discharges from a human body to any other part or between two objects can cause persistent disturbances or even destruction to sensitive electronics or controls. esd NX30 is an ESD gun that simulates ESD pulses at higher voltages, up to 30 kV, in air and contact discharge modes. Therefore, it satisfies requirements exceeding the EN/IEC 61000-4-2 test levels and complies with automotive test applications.
Standards:
- Automotive Standards: ISO 10605
- IEC / EN Basic Standards: IEC 61000-4-2
NSG 437
- Air- and contact-discharge to 30 kV
- Color touch panel control
- Advanced voltage-hold feature
- Activity log
- Light version with uncompromising test performance
- Compliant with a vast range of OEM and international standards
- Easily and quickly interchangeable discharge networks
- Discharge detector
Ergonomic design and advanced functionality. The NSG 437 ESD simulator is designed to sit comfortably in the operator’s hand, with operating conditions constantly displayed and accessible on a bright, clear color touch display. NSG 437 comprehensively fulfills virtually all international standard requirements. Based on over 60 optional discharge networks, the NSG 437 can meet any of today’s automotive manufacturers’ standards. The simulator is simple, convenient, and safe to use. The whole range of parameter settings, including polarity selection, freely adjustable pulse repetition, counter functions, and discharge detection, is available up to the maximum discharge voltage. The color touch display and keypad for parameter input show the precise functional and test data with user-selectable language for convenient and safe operation worldwide. The simulator contains variable threshold selection for accurate discharge detection. This detection feature can be switched off when testing EUTs with non-conductive surfaces, such as plastic housings. Pre-programmed settings for IEC 61000-4-2 and ISO 10605 ensure the simulator is automatically set up correctly and the appropriate discharge network is installed. The actual RC value is displayed at all times. Molded HV discharge networks in solid cases eliminate ionization and leakage current effects. Precisely tuned combinations of RC components guarantee wave shape parameters are tolerable. A unique activity log is included so that the types and numbers of ESD simulations can be easily scrolled through to check what has been tested and in what timeframe.
Standards:
- Automotive Standards: ISO 10605
- IEC / EN Basic Standards: IEC 61000-4-2
NSG 438/NSG 438A
- Air- and contact-discharge to 30 kV
- Battery tested to 30’000 discharges at 30 kV
- Color touch panel control
- Advanced voltage-hold feature
- Activity log
- Compliant with a vast range of OEM and international standards
- Built-in ISO self-calibration procedure
- Easily and quickly interchangeable discharge networks
Ergonomic design and advanced functionality. The NSG 438 ESD simulator is designed to sit comfortably in the operator’s hand, with operating conditions constantly displayed and accessible on a bright, clear color touch display. NSG 438 comprehensively fulfills virtually all international standard requirements. Based on over 60 optional discharge networks, the NSG 438 can meet any of today’s automotive manufacturers’ standards. The simulator is simple, convenient, and safe to use. The whole range of parameter settings, including polarity selection, freely adjustable pulse repetition, counter functions, and discharge detection, is available up to the maximum discharge voltage. The color touch display and keypad for parameter input show the precise functional and test data with user-selectable language for convenient and safe operation worldwide. The simulator contains variable threshold selection for accurate discharge detection. This detection feature can be switched off when testing EUTs with non-conductive surfaces, such as plastic housings. Pre-programmed settings for IEC 61000-4-2 and ISO 10605 ensure the simulator is automatically set up correctly and the appropriate discharge network is installed. The actual RC value is displayed at all times. Molded HV discharge networks in solid cases eliminate ionization and leakage current effects. Precisely tuned combinations of RC components guarantee wave shape parameters are tolerable. A unique activity log is included so that the types and numbers of ESD simulations can be easily scrolled through to check what has been tested and in what timeframe.
Standards:
- Automotive Standards: ISO 10605
- IEC / EN Basic Standards: IEC 61000-4-2